Model Number |
PPM-300, PPM-400 |
1. Trend : HR, SpO2, NIBP, Temp & Respiration trend selective. 24 hours memory storage (by 1 min.), Display range 2,4,6,12 hours scrollable, Graph : 10 min., 1,2,4,6, 12, 24 hours., Table : 6, 30, 90 min., 3, 6 hours
2. Display Parameter : Heart rate and alarm limit value, Percentage of SpO2 and alarm limit value, Blood pressure and alarm limit value, Lead-off detection, Trend of HR and bed ID, date & time, value & time for cursor point, event message, menu & menu information.
3. Power input : 100VAC~230VAC, 50/60 Hz.
4. Battery : Ni-MH Battery 12 VDC 3.8Ah, Duration time : less than 2 hours, Recharging time : more than 10 hours
5. Dimension : 231(W) * 215(H) * 134(D) mm
6. Weight : 4.3kg (including printer, battery)
7. Accessories : SpO2 sensor, adult reusable, ECG lead set, 3 lead, 3-lead ECG trunk cable, NIBP hose, NIBP cuff, adult/child reusable, NIBP cuff neonate adapter, Reusable temperature sensor, rectal, Reusable temperature sensor, skin.
8. ECG : Lead - 3 Lead selectable, Frequency response : Menu selective : Lower side 0.05Hz or 0.5Hz, Upper side 25Hz or 130Hz, Digital band-stop filter : on/off, Digital band-stop filter on (50/60Hz), Heart rate measurement range : 30-300 bpm, Accuracy : +/- 3bpm in whole detectable range, Input signal range : +/-5mV peak (DC offset :+/-300mV peak)
9. SpO2 : Probe - finger type reusable sensor, Measurement range : 50~100%, Accuracy : adult -71~100%:+/-2 digits, 50~70%:+/-3digits, neonate: +/-3% for readings between 70~95%, pulse rate accuracy : +/-3 bpm in whole detectable range, Setting time : wave out time : 2 sec, SpO2 percentage display : 7 sec, Averaging 5 beats
10. NIBP : Measurement mode : Oscillometric method, Cuff pressure display : 0~300mmHg, Blood pressure measurement range : adult - systolic : 30~270mmHg, mean arterial pressure : 20~255mmHg, diastolic : 10~245mmHg, neonate : systolic : 20~130mmHg, mean arterial pressure : 20~120mmHg, diastolic : 10~100mmHg, auto deflation pressure : audlt - 300mmHg, neonate - 150mmHg, measurement time <40 sec. at standard adult cuff & normal
11. RESP : bandwidth : 0.2 to 2 Hz (-6dB), respiration rate : adult/pediatric/neonate : 15~120bpm, accuracy : +/- 1rate/min @ 0~60 rate/min, resolution : 1 rate/min, respiration limit alarms : high range - adult/pediatric/neonate 5~120 bpm, low range : adult/pediatric/neonate 0~115 bpm, adjustment : 1 rate/min step for whole detectable range Apnea alarm.
12. Alarm : auto alarm limit : ECG, SpO2, NIBP, RESP, Temp., ECG Heart Rate : High limit 30~300 bpm, Low limit 30~290bpm, SpO2 : High saturation 52~100%, 2% interval, Low saturation 51~99%, 2% interval, NIBP : systolic high and low limit setting, 35~300/30~299, 1mmHg interval, diastolic high and low limit setting, 20~290/25~285, 1mmHg interval, mean high and low limit setting, 20~285/20~275, 1mmHg interval, RESP - high and low rate, Temperature - high and low rate 20~45 degree / 0~40 degree, Alarm on/off : suspend 3 min.
|
|
|
|
| |
|
|
|